Kun Liu weekly discussion with students [ATLAS]
Online
-
-
16:00
→
16:05
Introduction 5m
General items.
Speaker: Prof. Kun LIU (Tsung-Dao Lee Institute & Shanghai Jiao Tong University) -
16:05
→
16:15
ttWML and ttHML analyses status 10mSpeaker: Nihal BRAHIMI (Tsung-Dao Lee Institute & Shanghai Jiao Tong University)
ttWML analysis status:
- The group decided to fall back to the sub-optimal MG FxFx sample for ttW Gen and target a conf-conversion for the LHCTop/HWG meeting in December: https://indico.cern.ch/event/1219500/
- Unblinded fits are being rolled out for different setups (inclusive, differential,..). No showstoppers flagged so far. Latest inclusive results can be found here: https://indico.cern.ch/event/1221489/#2-inclusive-fit-updates (quite consistent with CMS within uncertainties)
- After conf-conversion, we will proceed to a paper targeting Moriond.
ttHML analysis status:
- Most of the efforts focussed on defining MVA discriminants to be used in the SRs
- Working with Jialin to come up with a good discriminant using DNN. Multiple configurations tested so far. Main bottleneck is the ttW CR and ttH SR definitions. Large anti-correlation (70%) observed between NF(ttH) and NF(ttW) which is not desirable.
- First dedicated (mini/skimmed) ttHML ntuples production now mostly ready (few jobs to be retried). Issues encountered when downloading the samples to eos and are being followed-up.
-
16:15
→
16:30
ttH analysis 15mSpeaker: jialin li
-
16:30
→
16:45
photon ID efficiency measurement & Zgamma analysis 15mSpeaker: Kang Liu
For Photon ID in Rel21
I have get ID efficiency of data17 and mc16d, but the result is not correct due to the smirnov transformation.
Now I reruning the grid job to build mc16d ntuples. it near to finish (95%).
After that I will recalculate the smirnov transformation, and then apply it on data17 and calculate ID efficiency.
For Photon ID in Rel22
Since the type of branch is vector<double>, what I need is only one of the vector. So I am learning the code of fill histogram in TnP.
Also I am trying to extract, for example, pt__NOSYS[0] in the Create finely-binned histograms code.
For CV Test
Due to the low resistance of the open circuit calibration of the LCR meter. For example, it should be in the order of G ohms normally, but after calibration, it is displayed in the order of M ohms.
After investigation, it is found that the capacitor of the adapter is short-circuited.
I have already purchased capacitors with the same specifications and asked Tang Jiannan to help me solder it.
We can restart CV test this Thursday.
-
16:45
→
17:00
silicon tracker: HGTD 15m
-
17:00
→
17:05
Non-academic items 5m
Anything else?
-
16:00
→
16:05