DarkSHINE:
HCAL hardware test: working on building a reasonable uniformity test procedure for plastic scintillator, so far the issue is that gamma source only give an undistinguishable (from background) photon yield while only a small portion of the beta source have enough energy to meet the requirement of coincident trigger.
CDR: move back to baseline 1.0 forsome materials
Hzy/Hyy*: a preliminary significance result obtained, 0.82 for MC23a+d Hzy, so as the limit. writing internal note
H2a4b: signal DAOD samples were done, working on the ntuples with Zelin. also preparing the LLP H2a2b vs. normal prompt H2a2b comparison to introduce in UEH
DarkSHINE
the results of baseline1.6
| EN_ECAL | PN_ECAL | GMM_ECAL | EN_target | PN_target | GMM_target |
MC events (with filter) | 97975842 |
| 217183412 | 499444293 | 380267123 | 9029044 |
1 track | 68382727 |
| 158964111 | 56703117 | 29986500 | 859 |
P_tag-P_rec>3 GeV | 12492 |
| 60477354 | 23743835 | 13310505 | 750 |
E_ECAL^total<1200MeV | 0 |
| 12735943 | 5482205 | 2729256 | 72 |
E_HCAL^total<10 MeV | 0 |
| 20 | 495611 | 184334 | 0 |
E_HCAL^(Max cell)< 0.3 MeV | 0 |
| 14 | 150072 | 51651 | 0 |
E_sideHCAL^total< 20MeV | 0 |
| 13 | 8831 | 4990 | 0 |
E_sideHCAL^(Maxcell)<1.5 MeV | 0 |
| 13 | 4402 | 2811 | 0 |
|
|
| 1.0368750 | 1298.2736 | 228.37618 |
|