[2025-01-18] For better promotion of the events, the categories in this system will be adjusted. For details, please refer to the announcement of this system. The link is https://indico-tdli.sjtu.edu.cn/news/1-warm-reminder-on-adjusting-indico-tdli-categories-indico

Shu's weekly group discussion

Asia/Shanghai
Tsung-Dao Lee Institute/N6F-N631 - Smart Classroom (Tsung-Dao Lee Institute)

Tsung-Dao Lee Institute/N6F-N631 - Smart Classroom

Tsung-Dao Lee Institute

Also at Room 603, New Science Building #5, Minhang Campus
15
Description

点击链接入会,或添加至会议列表:

https://cern.zoom.us/j/4042031778?pwd=N0RlZ0l3dGtEYk9zT25OWmlwVklSZz09

    • 1
      Status
      Speaker: Kang Yu (TDLI, SJTU)
      1. I have finished studying nuclear physics, which would help save more time in the future.
      2. I completed learning finite group representation theory. 
      3. Now I am reviewing the course on quantum field theory, and considering devoting more time back to research gradually.
    • 2
      Status
      Speaker: Linjing Duan (TDLI, SJTU)

      CEPC Zvvy nTGC

      • test the script for Ntuple production
      • example histograms of Missing_E (key observable) from Standard Model samples are shown,
      • cross-check with Danning, then produce Ntuples for all signal samples as preparation for further analysis and optimization

      Hyy*

      • New nominal MxAOD (signal and bkg) productions with new FFs are produced and downloaded.
      • start to rerun background modeling this week
    • 3
      Status
      Speaker: Jun Wei Lok (TDLI, SJTU)
    • 4
      Status
      Speaker: Zelin Yan (TDLI, SJTU)
    • 5
      Status
      Speaker: Bai-Hong Zhou (TDLI, SJTU)
    • 6
      Status
      Speaker: Xuliang Zhu (TDLI, SJTU)
    • 7
      Status
      Speaker: Zhiyu Zhao (TDLI, SJTU)

      DarkSHINE ECAL

      • A laser diode was used in place of a particle source and crystal to test the SiPM + front‑end electronics for precision across different signal amplitudes and baseline stability ; results for two AC‑coupling configurations (1 nF vs. 100 μF) were compared.
        • 100 μF coupling shows larger baseline drift; but the effect on small‑signal measurement is minor (~5%)
        • 1 nF configuration requires ≥100 MS/s sampling rate
        • 100 μF configuration requires ≥80 MS/s.
      • Next: We will validate the electronics design using the exist ADC readout board with 125 MS/s and 62.5 MS/s from USTC

      Analysis

      • Plan to involve pn_ecal process into BDT analysis
    • 8
      Status
      Speaker: Haidar Mas'ud Alfanda (TDLI, SJTU)

      DarkSHINE:

      • Debugging DSimu (disucssing with Xuliang) for the signal process when the target material is changed from W to other elements
      • Making preparations for the DarkSHINE winter mini-tutorial, the date is fixed for November 8

      CEPC:

      • Working with Xuliang for the jet reconstruction using JOI and jet tagging using PrimeTagSvc
    • REU: Undergrad Research Discussions
      • 9
        Status
        Speaker: Peixu Teng (SPA, SJTU)
        1. Still struggling with QFT. Now is at quantization in spinor fields.
        2. Going to write a document to fix a bug about a compatibility issues between the new version runtime library and the old version code in mathematica. I asked Chen Yifan about this problem but it still needs to make some changes.
        3. Next step i want to do is finding how to use the files outputed before to generate the simulated samples.
      • 10
        Status
        Speaker: Bingxian Li (SPA, SJTU)
      • 11
        Status
        Speaker: Chang Liu (University of California San Diego)