Kang:
Yang Lin, Yu Dian, Junhua and I did the CV test and became familiar with the entire test process. The capacitance test results of DarkSHINE sensor and USTC sensor are both lower than the previous results, about 1 order of magnitude. The specific reasons are still under investigation.
Regarding the problem that the DarkSHINE sensor is easily damaged: In addition to the structure of the sensor, it may be related to the excessive force used to insert the needle. As a result, the dielectric layer is easily damaged and short-circuited. For future testing, especially for DarkSHINE's sensor, the probe just needs to be in contact.

I have revised the draft: https://www.overleaf.com/project/6358f9a7b0a739132047752e. Added detailed description of signal to position distribution plot, about 250 words.
The previous method of "changing the initial direction of the Propagator-iterator by changing 3-momentum" in tagging reconstruction cannot be reproduced in the recoil area.
Specifically, the reconstruction efficiency is almost 100%, but the momentum distribution is completely inappropriate.
To do:
The Cartesian coordinates of truthHit and truthParticle are now rotated and then reconstructed directly